                                    315SWITCHGEAR & DISTRIBUTIONTogether we GENERATE VALUEIncoming device ratings up to 800A - outgoing device ratings up to 400ASpecification• Panelboards acc.to BS EN 61439-2• Panelboard is supplied as Form 4 Type 6 group mounted• 4-pole fully shrouded IPXXB plug-in busbar assembly• Busbar system DEKRA certified at Icw 50kA / 1s• Enclosure degree of protection IP3X (wallmounted)• MCCBs acc.to IEC/EN 60947-2• Switch disconnectors acc.to IEC/EN 60947-3Features• 6, 12 or 16 outgoing ways• Efficient design enables multiple number of outgoing options (SPN, TPN, 4P)• Standard off the shelf circuit breakers fit to the assembly• Outgoing devices: these panelboards utilise three frame sizes of MCCBs: NZM3 250-400A TPN/4P (fixed position, lower left/ right), NZM2 125-250A TPN/4P (completely variable), NZM1 SPN 16-125A and/or TPN/4P 20-160A (completely variable)• Easily reconfigurable to meet fully compartmentalised approach either Form 4 / Type 2 or Form 4 / Type 6• The design suits for top or bottom (as standard) incomer configuration• Removable end rails and gland plates for better access during installation• Wide range of extension boxes, plinths, metering, surge protection and earth leakage incomer options available• Provision for line side connection for sprinkler systems4-Pole Panelboards And Associated DevicesPart No. Description Associated incoming device Current rating (A)No. of outgoing ways based on NZM1 TPN/4P group mounted *EM4PB680 Incoming rating up to 800A, Outgoing ratings up to 400A NZMLW MCCB or NLW Switch Disconnector or direct lugs connection kit800 6EM4PB1280 12EM4PB1680 16Minimum ordering requirement: Panelboard + incoming device + incomer connection kit + feeder adapters + outgoing devices + blanking modules and associated components for Group Mounted or CompartmentalisedPart No. Poles Trip type Incoming device typeNZMLW-A630 3-pole NZMLW MCCB 630NZMLW-A800 800NZMN3-VX400 4-pole (3 phase andswitched neutral)NZMLW MCCB 630NZMN3-AX400 800• 50kA• Select appropriate incomer device from table below• Maximum cable capacity 2 x 300mm2• Thermal trip adjustment 0.5 to 1 x In, Magnetic trip adjustment 2 to 8 x InMCCB Incoming Device• 50kA• Select appropriate incomer device from table below• Maximum cable capacity 2 x 300mm2Switch Disconnector (Non-Automatic) Incoming DeviceMemshield 4 MCCB 4-Pole Panelboards and Associated DevicesPart No. Poles Trip type Incoming device typeNLW-630 3-pole NLW switch disconnector 630NLW-800 800NLW-4-630 4-pole NLW switch disconnector 630NLW-4-800 800eatoneatoneaton
                                
   309   310   311   312   313   314   315   316   317   318   319