Page 300 - Fegime - Electrical Product Guide Issue 1 V5
P. 300

                    SWITCHGEAR & DISTRIBUTION
Switch Disconnectors
Glasgow Fuse-Switch-Disconnectors & Switch-Disconnectors
All units are supplied with fuselinks or switchlinks fitted.Glasgow fuse switch disconnectors and switch disconnectors meet the constructional requirements for isolation of and are type tested to BS EN 60947-3. Five frame sizes are available to provide a range from 63A to 800A, with utilisation category AC22A and AC23A Ue 415V ratings. All units have retractable operating handles which drive overcentre mechanisms incorporating powerful operating springs. Flag “on-off” indication is provided and terminal cover shields prevent contact with live metal. Surface-mounting enclosures comprise heavy gauge steel body plates incorporating cast iron frame members and are rustprotected, with a light grey paint finish (RAL7004). Front access doors, which are detachable, are fitted with dust-excluding gaskets and are interlocked to prevent opening when the switch is ‘on’.
Glasgow Fuse-Switch-Disconnector
• Units are fitted with HRC Fuselinks of maximum rating but will accept fuselinks of a lower rating
• SPSN and TPSN indicate switched neutral
• Neutral makes first and breaks last
               -
100
160 (Use 200A Switch-Disconnector)
-
100MLK
63
63SB4
SB3 & SB4
63MLK
30
 63GNC
TPN
22
  64GC
TPSN
       101GNC
103GNC
SPSN
 TPN
100
100SD5
SB3, SB4, SO & SD5
100MLK
22
30
   104GC
TPSN
       Part No.
Nominal Unit
63
Nominal Rating, Ie AC21 (A)
125
Copper Switch Links Fitted
63MLK
Motor Ratings AC23A Ue 415V
kW
22
HP
151GNC
153GNC
SPSN
160
160SF6
SF3 & SF6
200MLK
90
125
  TPN
  154GC
       201GNC
TPSN
  SPSN
200
200SF6
SF3 & SF6
200MLK
90
125
      Exel 2 surface-mounting enclosures are fabricated from rust-protected sheet steel with a light grey paint finish. Removable blank top and bottom end plates (except for 20 and 32A top end plates which incorporate knockouts) and gasket doors give IP41 protection. Chromium-plated front operated handles, with “ON (I) OFF (O)” indication, and internal fixing enabling units to be mounted closely side by side. Interiors comprise porcelain bases fitted with non-ferrous conducting components.
SPSN indicates switched neutral. 1) 20A units are DC22.
-
-
30
-
Part No.
203GNC
304GC
Poles
TPN
TPSN
Nominal Unit Rating, Ie (A)
Eaton 415V Fuse(s) Fitted
  63GNL
204GC
TPSN
            103GNL
125
22
30
303GNC
TPN
315
315SF7
       403GNC
404GC
TPN
400
400SF8
* If DP fuse-switch-disconnectors are required, use SPSN and replace the supplied switch link with a compatible fuselink. Stud size: 63/100A = tunnel terminal, 160/200A = M10, 300/400 = M14, 500/800A = see page 148, “copper terminal plate”
tor Fuses
Suitable Fuselinks
SF3 & SF7
SF3 & SF8
Copper Switch Links Fitted
400MLK
400MLK
Motor Ratings AC23A Ue 415V
kW
110
110
HP
   61GNC
SPSN
 150
    150
  TPSN
     203GNL
200
315
200MLK
90
125
          -
315 (Use 400A Switch-Disconnector)
-
-
-
-
503GNC
603GNC
TPN
TPN
500
630
500SH9
630SH9
SH8 & SH9
-
630MLK
630MLK
225
       225
300
  300
       -
500 (Use 630A Switch-Disconnector)
-
-
-
-
604GC
804GC
TPSN
     403GNL
400
630
400MLK
110
150
       803GNC
TPN
TPSN
800
800SH10
SH8 & SH10
800MLK
300
400
                   603GNL
630
1000
400MLK
225
300
     803GNL
Exel 2
800
Switch-Disco
1000
nnecto
800MLK
rs & Swit
300
ch-Di
400
sconnec
        Part No.
Poles
Utilisation Category at Ue 415V to BS EN 60947-3
250V DC Rating to BS5419 DC23 (A)
Blank Endplate
AC22A (A)
 AC23A (A)
  -
 SPSN
20
11
 201)
 EP 842
 15AXD2
  DP
 15AXTN2
TPN
 -
 SPSN
 32
  22
  32
  -
  30AXD2
 DP
 30AXTN2
  TPN
 -
SPSN
63 39
-
63
EP 539
 60AXD2
 DP
 60AXTN2
 TPN
 -
  SPSN
  100
 - 52
 100
 -
100AXD2
DP
 100AXTN2
  TPN
 125AXTN2
 TPN
  125
  52
  -
  -
    Exel 2 switch disconnectors and switch-disconnector fuses meet the constructional requirements for isolation of and are type tested to BS EN 60947-3. Switches are of the quick make and break type, suitable for use on AC or DC. Units have removable moving contact assemblies to facilitate wiring.
 300
Together we
GENERATE VALUE
   